Description:
Argon is installed in pipes.
The gas is delivered from pressurized cylinders in building 1515
Function:
Argon comes with a pressure of 17 bar - when changing cylinder: only 13 bar.
The purity is 4.0 (99,99%)
In case of valve reduction there may be 0-5 bar or 0-10 bar in outlet pressure
Application:
Argon is utilized as an inert gas.
Pressure regulator and needle valve must be used to control pressure and flow in the same way as nitrogen.
FAQ/Typical errors:
If the cylinder is empty, contact "Butikken" - Mobile 9350 9047 (Jonas Rask Christensen).
In case of operational problems:
Send an e-mail to Building Service:
stbyg2service@au.dk
Contact:
Allan Madsen - mobile 2899 2015
Revised 11.11.2021
-